Code Description Solution
b5 Liquid valve temperature sensor error b5 solution
b7 Gas valve temperature sensor error b5 solution
C5 Malfunction protection of jumper cap b5 solution
dd Detection status of wrong connection of communication wire or malfunction of electronic expansion valve b5 solution
dn Wrong connection of communication wire or malfunction of electronic expansion valve b5 solution
E1 Compressor high pressure protection b5 solution
E2 Anti-freezing protection for evaporator
E3 Compressor low pressure protection b5 solution
E4 High discharge temperature protection of compressor b5 solution
E5 Whole unit overcurrent protection
E6 Communication malfunction b5 solution
E7 Mode conflict b5 solution
E8 High temperature and Overload protection b5 solution
E9 Cold air prevention protection b5 solution
EE ODU memory chip error b5 solution
ee Drive memory chip error b5 solution
EU Limit/decrease frequency due to high temperature of module b5 solution
F0 Refrigerant lacking or blockage protection of system b5 solution
F1 Indoor ambient temperature sensor error b5 solution
F2 Indoor evaporator temperature sensor error b5 solution
F3 Outdoor ambient temperature sensor error b5 solution
F4 Outdoor condenser temperature sensor error b5 solution
F5 Outdoor discharge temperature sensor error b5 solution
F6 Limit/decrease frequency due to overload b5 solution
F8 Decrease frequency due to overcurrent b5 solution
F9 Decrease frequency due to high air discharge b5 solution
FH Limit/decrease frequency due to antifreezing b5 solution
Fo Refrigerant recycling mode b5 solution
H1 Defrosting or oil return in heating mode b5 solution
H3 Compressor overload protection b5 solution
H4 Overload or overtemperature protection b5 solution
H5 IPM modular protection b5 solution
H6 Internal motor (fan motor) do not operate b5 solution
H7 Compressor desynchronizing b5 solution
HC PFC protection b5 solution
HE Compressor demagnetization protection b5 solution
JF Malfunction of detecting plate(WIFI) b5 solution
L3 Outdoor DC fan motor malfunction b5 solution
L9 Power protection b5 solution
LC Start failure of compressor b5 solution
Ld Compressor phase-lacking/phase-inverse protection b5 solution
LP Indoor unit and outdoor unit doesn't match b5 solution
oE PFC module temperature protection b5 solution
P0 Compressor Min frequency in test state b5 solution
P1 Compressor rated frequency in test state b5 solution
P2 Compressor maximum frequency in test state b5 solution
P3 Compressor intermediate frequency in test state b5 solution
P5 Compressor phase current protection b5 solution
P6 Master control and driver communication error b5 solution
P7 Driver module sensor error b5 solution
P8 Driver module temperature is too high b5 solution
PA AC current protection b5 solution
Pc Driver current error b5 solution
PH DC bus-bar high voltage protection b5 solution
PL DC bus-bar low voltage protection b5 solution
PU Capacitor or Charge loop error b5 solution
U1 Malfunction of phase current detection circuit for compressor b5 solution
U3 Malfunction of voltage dropping for DC bus-bar b5 solution
U5 Malfunction of complete unit's current detection b5 solution
U7 The four-way valve is abnormal b5 solution
U8 Malfunction of zero-cross detection circuit b5 solution